Surgical fixation of hip fractures– a novel technique for pre-operative planning (2025)

Journal of Orthopaedic Surgery and Research volume20, Articlenumber:391 (2025) Cite this article

  • 592 Accesses

  • Metrics details

Abstract

Purpose

The dynamic hip screw (DHS) is a widely used method for hip fracture stabilisation, but conventional DHS (CHDS) fixations may be limited by longer surgical duration and delayed recovery compared to minimally invasive DHS (MIDHS) fixations. We describe a novel low-cost surgical method that reduces intraoperative time, peri-operative complications, and improves overall patient outcomes.

Methods

A prospective double-blinded study included 15 patients who underwent surgical fixation of IT hip fractures using a 4-hole DHS system. All surgeries were performed at a tertiary referral hospital between January 2019 and April 2023 by surgeons with similar levels of experience. Main outcome measurements included tip-apex distance (TAD), surgery duration, haemoglobin loss, and hospital stay duration. Two independent assessors measured TAD using the post-operative anteroposterior and lateral radiographs. Kyle’s classification was used to categorize the IT fractures. IBM SPSS Statistics 26.0 for Mac (SPSS, Chicago, IL, USA) was used for the statistical analysis. Statistically significant difference was defined as p-value < 0.05.

Results

Both groups had similar baseline characteristics (p > 0.05). Both groups had similar complexity in fractures, but the mean surgical duration was significantly shorter (p = 0.019) (43.8 ± 12.3min) compared to the CDHS group (73.4 ± 18.2min). Postoperatively, there was no significant difference (p > 0.05) in hospital stay duration, haemoglobin (Hb) loss, or TAD.

Conclusions

MIDHS group had shorter surgical duration compared to CDHS group, with no significant difference in TAD, haemoglobin loss and hospital stay duration.

Introduction

Intertrochanteric hip fractures

Hip fractures are a commonly encountered injury in the field of orthopaedic surgery. Globally, the number of hip fractures is expected to reach 4.5million by the end of the year 2050, representing a significant increase from 1.26million cases in 1991 [1, 2]. Asia will account for more than half of all hip fractures, due to its rapidly aging population and higher life expectancy [3]. Hip fractures represent 0.1% (1.75million disability adjusted life years) of the global burden of disease world-wide [4].

Elderly adults are more susceptible to hip fractures as they tend to have reduced mobility and are more likely to have concomitant medical comorbidities [5,6,7]. In the United Kingdom (UK), after the age of 50, the lifetime risk of hip fracture is approximately 11% for women and 3% for men [8]. Medical comorbidities such as osteoporosis increase the likelihood of a fragility fracture [9,10,11]. An estimated 5.5million men and 22million women in the European Union (EU) alone were estimated to have osteoporosis in 2010. This led to 3.5million new fragility fractures, including 520,000 vertebral fractures, 610,000 forearm fractures, and 1,800,000 hip fractures [11]. Majority of hip fractures are caused by falls sustained during regular activities, with a male to female ratio of one to four [12, 13].

Minimally invasive dynamic hip screw fixations

The dynamic hip screw (DHS) is a common fixation technique used in the stabilisation of intertrochanteric hip fractures [14,15,16]. However, conventional dynamic hip screw (CDHS) fixation may be limited by longer surgical duration, more extensive soft tissue dissection, increased blood loss, delayed recovery, and prolonged hospital stays [17, 18].

The growing emphasis on optimising patient outcomes and minimisation of surgical trauma has given rise to the development and refinement of minimally invasive dynamic hip screw (MIDHS) fixation. Ideally, a minimally invasive technique should maintain the necessary fixation stability without noticeably shortening the femoral neck or causing rotation or tilting the femoral head [19]. Modification of current surgical techniques have been shown to reduce surgical duration, length of post-operative hospital stays, and blood loss [20, 21]. This prospective study aims to evaluate and compare clinical outcomes of patients who have undergone MIDHS with those who have undergone CHDS.

Tip-apex distance

Tip-apex distance (TAD) is the total distance measured from anteroposterior and lateral views, between the lag screw tip and the apex of the femoral head [22]. This is illustrated in Fig.1. For the purpose of the study, the known diameter of the hip screw was used to adjust for radiological magnification.

Illustration and formula of Tip-Apex Distance (TAD), adjusted for radiographic magnification [22]– Xap and Xlat represent the measured distances shown on the anteroposterior and lateral X-rays, respectively. Dtrue denotes the true diameter of the lag screw, while Dap and Dlat refer to the measured diameters of the lag screw as depicted on the anteroposterior and lateral X-rays

Full size image

Methods

A prospective single-blinded case control study was performed. Patients with intertrochanteric (IT) hip fractures who underwent surgical fixation with 4-hole DHS system in a tertiary referral hospital between January 2019 and April 2023 were identified and evaluated for inclusion in this trial. All cases were performed by Senior Orthopaedic Surgery Residents (Orthopaedic Surgery Registrars) of similar experience levels. Patients with complex fractures requiring open reduction were excluded from the study. The study protocol was approved by the Domain Specific Review Board (DSRB) of the institution under Reference number 2023/00715.

Novel technique for planning minimally invasive surgical fixation of hip fractures

The authors propose a novel MIDHS technique for treating IT hip fractures that considers the trajectory of the guidewire in all 3 planes– coronal, sagittal and axial, before any incision is made.

Cases were performed either under general or spinal anaesthesia. Prior to starting surgery, patients were positioned on a radiolucent fracture table, and all fractures were successfully reduced by closed manipulation under fluoroscopic control to 10 degrees of valgus on AP radiographs and < 58 degrees of posterior angulation on lateral radiographs. The skin surface markings were performed prior to preparation of the surgical field. The intraoperative imaging that was performed during the drawing of the skin markings were performed with the primary surgeon fully protected and comfortable, without wearing lead gown and thyroid shield yet, by standing behind panelled lead shields and/or outside the theatre leaded doors. The primary surgeon re-positioned the protractor as required in between imaging shots. Only the surgical assistant was required to hold a long rod for the purpose of achieving the lateral femur axis marking in the Clements-Nakayama view [23].

Antero-posterior surface marking– coronal consideration of plate position

A metal (stainless steel) protractor that was commercially purchased, was adjusted to the desired pre-templated degree– 135 or 150 degrees and laid directly on top of the patient. Antero-posterior (AP) intraoperative imaging (II) X-rays were taken to obtain and mark the surface position of the DHS plate (Figs.2 and 3). The vertical limb of the protractor was overlaid on the patient’s lateral femoral cortex with the vertical limb overlaid on the patient’s lateral femoral cortex, and the caput-collum-diaphyseal (CCD) line at the desired height, typically in the lower half of femoral neck and head region (Fig.2). The metallic nature of a protractor provided a satisfactory semi-lucent appearance, overlayed clearly over the femur, on the fluoroscopic image taken.

AP view of 135o metal protractor, the vertical limb was overlaid on the patient’s lateral femoral cortex, with the CCD line at the desired height, typically in the lower half of femoral neck and head region

Full size image

Anterior surface markings– Point A: Line towards centre of femoral head; Point B: Junction of axis of lines A and C; Point C: Along the lateral border of femur; Line D: Extension of line A beyond junction B; Line E: Perpendicular/ vertical line down posteriorly towards the floor

Full size image

Lateral surface marking– sagittal and axial consideration of plate position

With the Clements-Nakayama method [23]– a modified form of lateral view, resulted in a patient specific view of a collinear femoral head to the femoral shaft, which allowed the surgeon to take into consideration the amount of anteversion the specific patient had. With the II in the Clements-Nakayama tilt, a straight ruler was then used to mark the mid shaft of the femur along this view (Fig.4).

Lateral surface markings– Line E: Perpendicular/ vertical line down towards the floor; Point F: Intersection of lines D and E; Line G: Drawn along the mid axis of femur, referenced from the Clements-Nakayama method

Full size image

Surface marking– (a) Entry point of guidewire trajectory on skin surface (b) Length of potential incision

  1. (a)

    Point B, the intersection of the extrapolation of the oblique CCD line distally to meet the lateral surface marking line, was the entry point of the guidewire trajectory on the skin surface (Fig.3). This accounted for the thickness of the subcutaneous tissues and musculature of the specific patient.

  2. (b)

    Line E, a perpendicular line from the junction of the vertical limb and CCD angle (Figs.3 and 4), was made posteriorly, to meet the G line, which was the lateral surface marking line (Fig.4).

The line between the start of line E and point F, the G line, was the length of the potential skin incision to be made (Fig.4). In practice, depending on the thickness, and the turgor of the patient’s soft tissues, this line can be shortened up to 1–2cm proximally, and 2–4cm distally, and retractors may be used to allow for implant insertion.

Skin preparation was then done carefully, to avoid erasure of the markings during cleansing. Intraoperatively, after skin incision and exposure, the surgeon may additionally use a free K-wire, and insert it freehand, anterior to the cortex of the femur, to end in the femoral head. This served as a secondary visual guide for the anteversion of the guidewire to be inserted.

This abovementioned method enables surgeons to ascertain a more precise location and trajectory of the guidewire, starting from the entry point on the skin. This allows for a potentially smaller minimally invasive surgical incision. By accurately placing the guidewire with confidence on the first try, it allows surgeons to know the exact distal length of incision required for the DHS plate leading to reduction in soft tissue dissection.

Pre-operative parameters

Pre-operative clinical data for both groups is presented in Table1. Participants’ age, gender, body mass index (BMI), and premorbid ambulatory status were recorded. Participants’ comorbidities were summarised into a score using the Charlson comorbidity index, alongside an estimated 10-year survival rate which was calculated.

Full size table

Surgical outcome assessment

Post-operatively, patients received the same treatment and standard rehabilitation protocol established at the tertiary referral hospital. Surgical duration was defined as knife to skin, to completion of skin closure. All patients had their wounds closed in layers, with sutures only - no staplers were used. In all cases, AP and lateral radiographs were obtained post-operatively to assess fracture fixation and implant positioning. Pre- and post-operative haemoglobin levels were measured to assess the amount of blood loss. Two independent assessors measured the TAD using the post-operative AP and lateral radiographs. Discrepancies of > 2mm between the measurements by the two assessors were identified and remeasured. The Kyle’s classification was used to group the IT fractures into four categories– 1, stable 2-part IT fractures without displacement and tearing; 2, stable 3-part IT fractures with displacement and minimal tearing; 3, unstable 4-part IT fractures with displacement and posterior-medial breakage; 4, unstable 4-part IT fractures with posterior displacement, posterior-medial breakage and inferior-trochanterion component [24].

Statistical analysis

IBM SPSS Statistics 26.0 for Mac (SPSS, Chicago, IL, USA) was used for the statistical analysis. Analysis of the categorical variables (Kyle’s classification and ASA classification) was performed using the Chi square test since n > 5. Analysis of the continuous variables comprising of non-parametric data (Tip-apex distance, duration of surgery, days between injury and surgery, days of hospital stay, Hb loss, number of intraoperative radiographs and cumulative duration of radiation exposure) was performed using the Mann-Whitney U test. 95% confidence interval was used to provide us with the likely values of the true population mean. The significance tests for each were all two-tailed. Statistically significant difference was defined as p-value < 0.05.

Results

15 patients met the inclusion criteria and were sorted accordingly into the MIDHS or CDHS group. All MIDHS surgeries were performed by a single surgeon, a second- to third-year Senior Orthopaedic Resident (Orthopaedic Surgery Registrar). Other surgeons with similar experience performed CDHS fixation on the control group. Both groups utilised the same implants, sets and tools. The pre- and post-operative clinical information were documented for each case.

The MIDHS and CDHS groups comprised 5 and 10 patients respectively. Both groups had comparable preoperative demographics, body mass index, comorbidity factors (Charlson Comorbidity index), premorbid ambulatory status, injury mechanism, fracture pattern and time elapsed from injury to surgery. The American Society of Anaesthesiologists (ASA) classification for both groups was also similar. The ASA classification for one patient was not recorded and was excluded from the study (Table1). MIDHS group had a similar complexity of fractures compared to the CDHS group (p = 0.097). However, the mean surgical duration in the MIDHS group was significantly shorter as compared to the CDHS group (43.7 vs. 73.4min, p = 0.019).

No significant difference was found for the following outcome measures: duration of hospital stays (p = 0.310), TAD (p = 0.594), haemoglobin (Hb) loss (p = 0.898), number of intraoperative radiographs (p = 0.825) and cumulative duration of radiation exposure (p = 0.604). The surgical and post-surgical data for both groups is summarised in Table2. Lower mean TAD, Hb loss and duration of hospital stay were observed in the MIDHS group, but the outcomes were not statistically significant.

Full size table

Discussion

Several methods and techniques have been described for the surgical treatment of IT fractures [25,26,27]. DHS is commonly used for treating IT fractures in the elderly as it allows for early remobilisation, is easy to use, and has low complication rates [28, 29]. However, it is imperative to note that certain parameters such as patient’s age, the amount of time elapsed between the injury and surgery, and the presence of medical comorbidities also play a role in treatment outcomes [30]. Several studies have explored MIDHS fixations with favourable clinical outcomes. However, there are various limitations can be identified in the existing literature.

A similar study conducted by Wong et al. [21], the MIDHS group had considerably smaller drops in Hb levels, lower rate of blood transfusions, significantly lower pain scores on the third postoperative day, and significantly lesser overall analgesic use in the first three days. However, Wong’s MIDHS method showed no significant difference in surgical duration. Our MIDHS method records lower mean surgical duration in surgeons of similar surgical experience, suggesting that it may be a superior technique. This may be due to the additional consideration of the anteversion of the femur, with the incorporation of the Clements-Nakayama view. Although Wong’s MIDHS group average hospital stay was shorter than that of the CDHS group, neither the difference in complication rates nor the difference in hospital stay duration were statistically significant.

Ho et al. [31] described a minimally invasive technique with significant shortening in the duration of surgery and length of hospital stay. However, the paper considered 2-hole, 3-hole, and 4-hole DHS and is not fully relevant to our current study which only studies the use of a 4-hole DHS system. Furthermore, the TAD and Hb loss were also reported to be statistically insignificant as well. This is concurrent with our findings.

Lee et al. [18] reported positive findings with MIDHS with statistically significant haemoglobin loss and length of hospital stay which is inconsistent with our data. However, unlike our novel technique, this study did not prove a statistically significant reduction in surgical duration. Furthermore, they preferred the use of 3-hole side plates, whereas this study used 4-hole side plates. Thus, a direct comparison to their study cannot be made.

Wang et al. [32] reports a MIDHS technique with significantly lower average surgical duration, incision length, blood transfusion rate, and post-operative stay. While Wang had a significantly shorter mean surgical time in the MIDHS group, the mean of 64.8min was much higher than that of ours, with a mean of 43.8min.

Our MIDHS group also showed superior outcomes in mean TAD, haemoglobin loss, and length of hospital stay, though they were not statistically significant. This shows that our novel technique is indeed an improvement to existing surgical techniques and increases the overall standard of care. While our mean TAD is better, there is no consensus in literature regarding the minimum clinically important difference (MCID) with regards to TAD.

Limitations

Although the results proved that the proposed technique produced better results as compared to CDHS, there were several limitations of the study as well as the novel MIDHS technique. Firstly, the statistical power of the study was reduced given a small sample size (n = 15). The surgical technique was conducted by a single surgeon, and hence the reproducibility of the results must be validated by other surgeons of the same level of experience. Although a larger sample size would be ideal, the surgeon has shown that the duration of surgery was clinically and statistically significantly shorter as compared to the CDHS. Although more intraoperative images were taken pre-incision using our novel method, this allowed for fewer intraoperative images, and fewer total images to be taken after skin incision. This reduced wound exposure time, blood loss, and attempts for entry of the guidewire.

A further limitation for both the MIDHS and CDHS groups was the lack of recorded data on the number of repeated attempts needed to achieve satisfactory guidewire placement. However, in the author’s experience, a maximum of two to three passes with minimal adjustment were needed to reach the optimal position, due to improved accuracy from the surface markings. The Kyle screw position was not examined in this study. However, MIDHS had a lower TAD as compared to the CDHS control group, which was the most important independent factor when assessing for the optimal positioning of the DHS. All patients included in the study reached union with appropriate TAD targets of < 25mm achieved. Lastly, the Harris hip score and Elderly mobility scale, which assess long term rehabilitative progress of surgical patients, were not included as outcome measurements.

Conclusion

Minimally invasive surgeries are known to reduce post-operative complications and morbidity. Our MIDHS technique proved that in comparison to the CDHS, there was no significant difference in hospital stay duration, haemoglobin loss or TAD. However, there was a significant reduction in surgical duration. Furthermore, the number of passes before guidewire positioning could affect the clinical outcome of the patient and therefore the reliability of the conclusion. This suggests that to ascertain and validate our study further, we need to increase our cohort size, include the number of passes made in both case series, and follow up with our patients over the long term.

Data availability

No datasets were generated or analysed during the current study.

Abbreviations

AP:

Antero-posterior

BMI:

Body mass index

CCD:

Caput-collum-diaphyseal

CDHS:

Conventional dynamic hip screw

DHS:

Dynamic hip screw

DSRB:

Domain Specific Review Board

EU:

European Union

Hb:

Haemoglobin

IT:

Inter-trochanteric

MCID:

Minimum clinically important difference

MIDHS:

Minimally invasive dynamic hip screw

TAD:

Tip-apex distance

UK:

United Kingdom

References

  1. Tan LT, Wong SJ, Kwek EB. Inpatient cost for hip fracture patients managed with an orthogeriatric care model in Singapore. Singap Med J Mar. 2017;58(3):139–44. https://doi.org/10.11622/smedj.2016065.

    Article Google Scholar

  2. Veronese N, Maggi S. Epidemiology and social costs of hip fracture. Injury Aug. 2018;49(8):1458–60. https://doi.org/10.1016/j.injury.2018.04.015.

    Article Google Scholar

  3. Kanis JA, Odén A, McCloskey EV et al. A systematic review of hip fracture incidence and probability of fracture worldwide. Osteoporosis International. 2012/09/01 2012;23(9):2239–2256. https://doi.org/10.1007/s00198-012-1964-3.

  4. Johnell O, Kanis JA. An estimate of the worldwide prevalence, mortality and disability associated with hip fracture. Osteoporos Int Nov. 2004;15(11):897–902. https://doi.org/10.1007/s00198-004-1627-0.

    Article CAS Google Scholar

  5. Chen M, Li Y, Yang Y, Zhuang W. Analysis of the risk factors for contralateral refracture after hip fracture surgery in elderly individuals: a retrospective study. J Orthop Surg Res Oct. 2024;23(1):681. https://doi.org/10.1186/s13018-024-05177-x.

    Article Google Scholar

  6. Chen YP, Kuo YJ, Hung SW, et al. Loss of skeletal muscle mass can be predicted by sarcopenia and reflects poor functional recovery at one year after surgery for geriatric hip fractures. Injury Nov. 2021;52(11):3446–52. https://doi.org/10.1016/j.injury.2021.08.007.

    Article Google Scholar

  7. Jaul E, Barron J, Rosenzweig JP, Menczel J. An overview of co-morbidities and the development of pressure ulcers among older adults. BMC Geriatrics. 2018/12/11 2018;18(1):305. https://doi.org/10.1186/s12877-018-0997-7

  8. Riemen AH, Hutchison JD. The multidisciplinary management of hip fractures in older patients. Orthop Trauma Apr. 2016;30(2):117–22. https://doi.org/10.1016/j.mporth.2016.03.006.

    Article Google Scholar

  9. Liu T, Zhang X, Zhang J, Ye P, Yang M, Tian M. Effect of the orthogeriatric co-management on older hip fracture patients with Multimorbidity: a post-hoc exploratory subgroup analysis of a non-randomised controlled trial. J Orthop Surg Res Nov. 2024;21(1):780. https://doi.org/10.1186/s13018-024-05263-0.

    Article Google Scholar

  10. Han X, Han L, Chu F, et al. Predictors for 1-year mortality in geriatric patients following fragile intertrochanteric fracture surgery. J Orthop Surg Res Oct. 2024;30(1):701. https://doi.org/10.1186/s13018-024-05219-4.

    Article Google Scholar

  11. M vO. Osteoporosis and the nature of fragility fracture: an overview. In: Hertz K, Santy-Tomlinson J, editors. Fragility fracture nursing: holistic care and management of the orthogeriatric patient. [Internet]: Springer; 2018.

    Google Scholar

  12. Emmerson B, Varacallo M, Inman D. Hip fracture overview. Internet: StatPearls Publishing; 2023.

    Google Scholar

  13. Orwig DL, Chan J, Magaziner J. Hip Fracture and Its Consequences: Differences Between Men and Women. Orthopedic Clinics of North America. 2006/10/01/ 2006;37(4):611–622. https://doi.org/10.1016/j.ocl.2006.08.003.

  14. Maffulli N, Aicale R. Proximal femoral fractures in the elderly: A few things to know, and some to forget. Med (Kaunas) Sep. 2022;20(10). https://doi.org/10.3390/medicina58101314.

  15. Kyle RF, Cabanela ME, Russell TA, et al. Fractures of the proximal part of the femur. Instr Course Lect. 1995;44:227–53.

    CAS PubMed Google Scholar

  16. Bolhofner BR, Russo PR, Carmen B. Results of intertrochanteric femur fractures treated with a 135-degree sliding screw with a two-hole side plate. J Orthop Trauma Jan. 1999;13(1):5–8. https://doi.org/10.1097/00005131-199901000-00002.

    Article CAS Google Scholar

  17. Quaranta M, Miranda L, Oliva F, Migliorini F, Pezzuti G, Maffulli N. Haemoglobin and transfusions in elderly patients with hip fractures: the effect of a dedicated orthogeriatrician. J Orthop Surg Res Jun. 2021;16(1):387. https://doi.org/10.1186/s13018-021-02524-0.

    Article Google Scholar

  18. Lee YS, Huang HL, Lo TY, Huang CR. Dynamic hip screw in the treatment of intertrochanteric fractures: a comparison of two fixation methods. Int Orthop Oct. 2007;31(5):683–8. https://doi.org/10.1007/s00264-006-0248-y.

    Article Google Scholar

  19. Stoffel K, Zderic I, Gras F, et al. Biomechanical evaluation of the femoral neck system in unstable Pauwels III femoral neck fractures: A comparison with the dynamic hip screw and cannulated screws. J Orthop Trauma Mar. 2017;31(3):131–7. https://doi.org/10.1097/bot.0000000000000739.

    Article Google Scholar

  20. Alobaid A, Harvey EJ, Elder GM, Lander P, Guy P, Reindl R. Minimally invasive dynamic hip screw: prospective randomized trial of two techniques of insertion of a standard dynamic fixation device. J Orthop Trauma Apr. 2004;18(4):207–12. https://doi.org/10.1097/00005131-200404000-00003.

    Article CAS Google Scholar

  21. Wong T-C, Chiu Y, Tsang W-L, Leung W-Y, Yeung S-H. A double-blind, prospective, randomised, controlled clinical trial of minimally invasive dynamic hip screw fixation of intertrochanteric fractures. Injury. 2009;40(4):422–7. https://doi.org/10.1016/j.injury.2008.09.029.

    Article PubMed Google Scholar

  22. Geller JA, Saifi C, Morrison TA, Macaulay W. Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures. International Orthopaedics. 2010/06/01 2010;34(5):719–722. https://doi.org/10.1007/s00264-009-0837-7

  23. Clements RW, Nakayama HK. Radiographic methods in total hip arthroplasty. Radiol Technol Mar-Apr. 1980;51(5):589–600.

    CAS Google Scholar

  24. Botean AI, Takacs IA, Hardau M. The study of massive trochanterion fractures. Berlin Heidelberg: Springer; 2011. pp. 294–7.

    Google Scholar

  25. Audigé L, Hanson B, Swiontkowski MF. Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices. Int Orthop. 2003;27(4):197–203. https://doi.org/10.1007/s00264-003-0457-6.

    Article PubMed PubMed Central Google Scholar

  26. Aune AK, Ekeland A, Odegaard B, Grøgaard B, Alho A. Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperations in a prospective, randomized study of 378 patients. Acta Orthop Scand Apr. 1994;65(2):127–30. https://doi.org/10.3109/17453679408995418.

    Article CAS Google Scholar

  27. Barquet A, Francescoli L, Rienzi D, López L. Intertrochanteric-subtrochanteric fractures: treatment with the long gamma nail. J Orthop Trauma Jun-Jul. 2000;14(5):324–8. https://doi.org/10.1097/00005131-200006000-00003.

    Article CAS Google Scholar

  28. Mäkinen TJ, Gunton M, Fichman SG, Kashigar A, Safir O, Kuzyk PRT. Arthroplasty for Pertrochanteric Hip Fractures. Orthopedic Clinics of North America. 2015/10/01/ 2015;46(4):433–444. https://doi.org/10.1016/j.ocl.2015.06.001.

  29. Jensen JS, Sonne-Holm S, Tøndevold E. Unstable trochanteric fractures. A comparative analysis of four methods of internal fixation. Acta Orthop Scand Dec. 1980;51(6):949–62. https://doi.org/10.3109/17453678008990900.

    Article CAS Google Scholar

  30. Marmor M, Guenthner G, Rezaei A, Saam M, Matityahu A. Reporting on quality of reduction and fixation of intertrochanteric fractures-A systematic review. Injury Mar. 2021;52(3):324–9. https://doi.org/10.1016/j.injury.2021.02.014.

    Article Google Scholar

  31. Ho M, Garau G, Walley G, et al. Minimally invasive dynamic hip screw for fixation of hip fractures. Int Orthop Apr. 2009;33(2):555–60. https://doi.org/10.1007/s00264-008-0565-4.

    Article Google Scholar

  32. Wang JP, Yang TF, Kong QQ, et al. Minimally invasive technique versus conventional technique of dynamic hip screws for intertrochanteric femoral fractures. Arch Orthop Trauma Surg May. 2010;130(5):613–20. https://doi.org/10.1007/s00402-009-0978-6.

    Article Google Scholar

Download references

Funding

This research received no external funding.

Author information

Authors and Affiliations

  1. Department of Orthopaedic Surgery, National University Hospital, 5 Lower Kent Ridge Rd, Singapore, 119074, Singapore

    Zi Qiang Glen Liau&Seth Ian Sim

  2. Department of Orthopaedic Surgery, Alexandra Hospital, 378 Alexandra Rd, 159964, Singapore, Singapore

    Zi Qiang Glen Liau

  3. Yong Loo Lin School of Medicine, National University of Singapore, Singapore, 117597, Singapore

    Kamaraj Thirukumaran&Alexander Shao-Rong Pang

Authors

  1. Zi Qiang Glen Liau

    View author publications

    You can also search for this author inPubMedGoogle Scholar

  2. Kamaraj Thirukumaran

    View author publications

    You can also search for this author inPubMedGoogle Scholar

  3. Seth Ian Sim

    View author publications

    You can also search for this author inPubMedGoogle Scholar

  4. Alexander Shao-Rong Pang

    View author publications

    You can also search for this author inPubMedGoogle Scholar

Contributions

Conceptualisation, Z.Q.G.L., K.T., A.S.-R.P., S.I.S.; Formal analysis, K.T., A.S.-R.P., S.I.S., Z.Q.G.L.; Writing—original draft preparation and design figures, K.T., A.S.-R.P., S.I.S., Z.Q.G.L.; Writing—review and editing, S.I.S., Z.Q.G.L.; Supervision, Z.Q.G.L. All authors have read and agreed to the published version of the manuscript.

Corresponding author

Correspondence to Zi Qiang Glen Liau.

Ethics declarations

Ethics approval and consent to participate

The study protocol was approved by the Domain Specific Review Board (DSRB) of the National Healthcare Group (NHG) under Reference number 2023/00715.

Human ethics and consent to participate

All procedures performed in this study involving human participants were in accordance with the ethical standards of the institutional research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. Informed consent for the procedure was obtained from all individual participants involved in the study.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Surgical fixation of hip fractures– a novel technique for pre-operative planning (5)

Cite this article

Liau, Z., Thirukumaran, K., Sim, S. et al. Surgical fixation of hip fractures– a novel technique for pre-operative planning. J Orthop Surg Res 20, 391 (2025). https://doi.org/10.1186/s13018-025-05803-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13018-025-05803-2

Keywords

  • Femur
  • Intertrochanteric fractures
  • Dynamic hip screw fixation
  • Minimally invasive surgery
Surgical fixation of hip fractures– a novel technique for pre-operative planning (2025)

References

Top Articles
Latest Posts
Recommended Articles
Article information

Author: Manual Maggio

Last Updated:

Views: 6165

Rating: 4.9 / 5 (69 voted)

Reviews: 84% of readers found this page helpful

Author information

Name: Manual Maggio

Birthday: 1998-01-20

Address: 359 Kelvin Stream, Lake Eldonview, MT 33517-1242

Phone: +577037762465

Job: Product Hospitality Supervisor

Hobby: Gardening, Web surfing, Video gaming, Amateur radio, Flag Football, Reading, Table tennis

Introduction: My name is Manual Maggio, I am a thankful, tender, adventurous, delightful, fantastic, proud, graceful person who loves writing and wants to share my knowledge and understanding with you.